Fire Fighting System Cost in Egypt — Instant Price Calculator
A fire fighting system combines detection with active suppression: sprinklers for general areas or FM200 clean agent for server rooms, archives and electrical rooms. The price depends on the protected area and space type, how many detectors, call points and sounders are needed, the size of the addressable control panel, the sprinkler head count and piping area or the suppressed volume in cubic metres, and add-ons such as an electric fire pump, diesel backup pump, GRP water tank, emergency lighting, commissioning or an annual maintenance contract. Use the calculator below for an instant estimate in EGP or USD.
- Step 1 of 3Zones & Systems
- Step 2 of 3Add-ons
- Step 3 of 3Your Quote
Add one zone per area or room. Enter the space type and area — detector count, sprinkler heads, and call points are calculated automatically per NFPA 72. You can override detector count manually.
Cost Summary
🇪🇬 Egypt — EGP
Total Estimate
0 EGP
One-time system cost
⚠️ Estimate only. Final pricing subject to site survey and confirmation.
Detection Coverage Reference
Cost overview
A fire fighting system combines detection with active suppression: sprinklers for general areas or FM200 clean agent for server rooms, archives and electrical rooms. The price depends on the protected area and space type, how many detectors, call points and sounders are needed, the size of the addressable control panel, the sprinkler head count and piping area or the suppressed volume in cubic metres, and add-ons such as an electric fire pump, diesel backup pump, GRP water tank, emergency lighting, commissioning or an annual maintenance contract. Use the calculator below for an instant estimate in EGP or USD.
Current prices start at 180 EGP for the sprinkler piping & labour and reach 210,000 EGP for the add-on: diesel backup pump.
How this estimate is calculated
- The protected area and space type set how many detectors and call points the layout needs.
- Each detector, call point and sounder is priced per unit, with installation labour added per detector.
- The addressable panel is selected by loop count (2, 4 or 8 loops) and installed once per project.
- Sprinkler protection is priced by head count plus piping and labour per square metre; FM200 protection is priced per cubic metre of the protected volume.
- Add-ons are charged per project or per zone as listed below.
Current price list
These are the same prices the calculator above uses. Listed in EGP, with the USD equivalent at today's exchange rate.
| Item | Unit | Price (EGP) | USD |
|---|---|---|---|
| Addressable Smoke Detector | per unit | 1,500 EGP | $31 |
| Heat Detector | per unit | 1,200 EGP | $25 |
| Multi-Sensor Detector | per unit | 2,100 EGP | $43 |
| Flame Detector | per unit | 9,000 EGP | $186 |
| Manual Call Point | per unit | 900 EGP | $19 |
| Sounder / Strobe | per unit | 1,500 EGP | $31 |
| Detector installation labour | per unit | 600 EGP | $12 |
| 2-Loop Panel | per unit | 24,000 EGP | $497 |
| 4-Loop Panel | per unit | 42,000 EGP | $869 |
| 8-Loop Panel | per unit | 72,000 EGP | $1,490 |
| Panel installation labour | per project | 12,000 EGP | $248 |
| Sprinkler head (supply + fitting) | per unit | 900 EGP | $19 |
| Sprinkler piping & labour | per m² | 180 EGP | $4 |
| FM200 / clean agent suppression | per m³ | 1,050 EGP | $22 |
| Add-on: Electric Fire Pump (1,000 LPM) | per project | 150,000 EGP | $3,105 |
| Add-on: Diesel Backup Pump | per project | 210,000 EGP | $4,347 |
| Add-on: GRP Water Tank (20 m³) | per project | 90,000 EGP | $1,863 |
| Add-on: Emergency Lighting | per zone | 4,800 EGP | $99 |
| Add-on: Commissioning & Testing | per project | 30,000 EGP | $621 |
| Add-on: Annual Maintenance Contract | per zone | 7,200 EGP | $149 |
Frequently asked questions
How much does a fire fighting system cost in Egypt?
It scales with the protected area and the suppression method. The table above shows current EGP prices for detectors, panels, sprinkler heads, sprinkler piping per square metre and FM200 per cubic metre; the calculator combines them for your building.
Sprinklers or FM200 clean agent — which do I need?
Water sprinklers suit general occupancies such as offices, retail and warehouses. FM200 clean agent is used where water would destroy the contents: server rooms, electrical rooms, archives and laboratories. Many buildings use both, zone by zone.
How many detectors does my building need?
Detector spacing depends on ceiling height, area and occupancy. The calculator proposes a count from the area and space type you enter; the final layout follows the approved design drawings.
Do I need a fire pump and water tank?
Sprinkler systems need a guaranteed water supply at pressure. Where the municipal supply is not sufficient, an electric pump, a diesel backup pump and a GRP tank are added; all three are optional add-ons in the calculator.
Is commissioning and testing included?
Only when you select the commissioning and testing add-on, which covers functional testing and handover documentation of the installed system.
What does the annual maintenance contract cover?
Scheduled inspection and functional testing of the detection and suppression equipment in each contracted zone, priced per zone per year.
Do you work outside Egypt?
Yes. Switch the calculator to the International panel for the same price list in USD at today's rate; installation outside Egypt is quoted per project.
Is the estimate a formal quotation?
It is priced from the published list above. Pay for your configured package and our team issues the formal quotation; any pricing changes after the site survey and approved fire fighting design are listed in that quote.